Produk
Tipe A Sisa Circuit Breaker
  • Tipe A Sisa Circuit BreakerTipe A Sisa Circuit Breaker
  • Tipe A Sisa Circuit BreakerTipe A Sisa Circuit Breaker
  • Tipe A Sisa Circuit BreakerTipe A Sisa Circuit Breaker

Tipe A Sisa Circuit Breaker

Tuku CDADA Tipe A Sisa Circuit breaker saka Shanghai DADA Electric, kita duwe luwih saka 40 taun pengalaman, bisa dadi supplier Panjenengan. Sertifikasi EN/IEC 61008-1, 2P/4P, 16–100A, 30mA/100mA pilihan. Ndeteksi AC + pulsating DC bocor. IP20, pemasangan rel DIN, tahan surge. Cocog kanggo omah modern & panel komersial.

Mesthekake keamanan pribadi lan geni sing lengkap ing lingkungan sing sugih elektronik saiki kanthi CDADA Type A Residual Current Circuit Breaker (RCCB), kita bisa menehi rega langsung pabrik. Iku ngluwihi deteksi kebocoran AC dhasar - bisa dipercaya ing loro AC sinusoidal lan arus residu DC pulsating sing digawe dening piranti umum kaya pangisi daya telpon, driver LED, komputer, lan piranti kacepetan variabel.

Kasedhiya ing konfigurasi 2P (1+N) lan 4P (3+N) kanthi arus dirating saka 16A nganti 100A lan sensitivitas 10mA, 30mA, 100mA, utawa 300mA, dirancang kanggo instalasi omah modern, kantor, lan komersial ringan.

Kanthi rating short-circuit bersyarat 6kA, proteksi IP20, lan opsi terminal dual (lug/pin), RCCB Tipe A CDADA nggabungake desain sing aman, linuwih, lan ramah-instaler—kabeh didhukung dening kepatuhan global.

Type A Residual Current Circuit Breaker

Spesifikasi Utama

Tipe produk: Tipe A RCCB (Residual Current Circuit Breaker tanpa proteksi arus lebih)
Standar: EN/IEC 61008-1
Kutub: 2P (1+N) utawa 4P (3+N)
Rated Saiki (Ing): 16A, 25A, 32A, 40A, 63A, 80A, 100A
Tegangan Rated: 2P:
230 V AC 4P:
230/400 V AC Sensitivitas Sisa (I△n):
10mA, 30mA, 100mA, 300mA Arus Non-Tripping:
0,5 × I△n Wektu Perjalanan ing I△n:
≤ 0,1 detik Arus Sirkuit Pendek Bersyarat (Inc):
6kA Kapasitas Nggawe & Breaking (I₄m):
500A (kanggo Ing ≤ 40A)
630A (kanggo Ing ≥ 63A)
Tegangan Tahan Impuls (Uimp):
6000V Suhu operasi:
-25°C nganti +40°C Gelar Proteksi:
IP20 Pemasangan:
Rel DIN 35mm (sesuai karo EN 60715) Terminal:
Jinis lug utawa jinis Pin, ndhukung kabel nganti 35mm² Indikator Visual:
Abang = ON (kontak ditutup), Ijo = OFF (kontak mbukak) Mekanisme Trip:
Pelepasan elektromagnetik - kekebalan kanggo fluktuasi voltase


Kenapa Pilih CDADA Tipe A RCCB?

★  Ndeteksi Ancaman Bocor Donya Nyata

Ora kaya piranti AC Tipe dhasar, CDADA Tipe A nanggapi AC lan DC pulsating-penting kanggo safety ing omah lan kantor sing diisi pasokan listrik, inverter, lan pangisi daya EV.

★ Ora Ana Gangguan Tripping

Nyaring majeng njamin kekebalan marang lonjakan voltase lan arus transien sing ora mbebayani, nalika isih njamin wektu trip <0.1s kanthi sensitivitas sing dirating.

★ Clear Status Visual

Indikator posisi kontak abang/ijo ngidini verifikasi cepet status breaker-kritis sajrone pangopènan utawa pamriksan darurat.

★ Kabel Fleksibel & Kompatibilitas Tinggi

Ndhukung terminal lug utawa pin lan kabel 35mm², dadi kompatibel karo busbar lan konduktor fleksibel ing panel modern.

Type A Residual Current Circuit Breaker

★ Two paku keling tambahan

tambah kaku saka casing ing wilayah sambungan konduktor amarga loro rivets tambahan lan faceplate ngalangi

Type A Residual Current Circuit Breaker

★ DIN ril ngawat-ngawati

Instalasi cepet lan linuwih tambahan snapping ing rel DIN amarga kait karo ngunci pindho

Type A Residual Current Circuit Breaker

★ Kepatuhan Global, Nilai Lokal

Disertifikasi kanggo IEC / EN 61008-1, cocog kanggo pasar EU, Timur Tengah, Afrika, lan Asia - kanthi rega kompetitif saka pabrikan China sing dipercaya.

Type A Residual Current Circuit Breaker

Aplikasi Khas

Type A Residual Current Circuit BreakerOmah Modern: Sirkuit soket karo TV, laptop, elektronik pawon

Type A Residual Current Circuit BreakerKantor: ruang IT, stopkontak stasiun kerja

Type A Residual Current Circuit BreakerEceran: Sistem POS, signage digital, lampu LED

Type A Residual Current Circuit BreakerTitik Pangisian Daya EV: Lapisan proteksi dhasar (dipasangake karo piranti arus luwih)

Type A Residual Current Circuit BreakerInstalasi sing bisa dianyari: Inverter surya ngasilake kebocoran DC pulsa

Type A Residual Current Circuit Breaker

FAQ

Q1: Apa bedane antarane Tipe A lan Tipe AC RCDs?

A1: Tipe AC mung ndeteksi kebocoran AC sinusoidal sing lancar. Tipe A ndeteksi AC lan DC pulsating (contone, saka rectifier ing pangisi daya telpon, driver LED, utawa mesin cuci). Kanggo sirkuit apa wae sing nganggo elektronik, Tipe A dibutuhake dening kode listrik modern.


Q2: Apa RCD Tipe A 30mA cukup kanggo perlindungan pribadi?

A2: Nggih. 30mA minangka ambang standar kanggo proteksi kejut sing nylametake urip saben IEC. Tipe A CDADA njamin kerjane sanajan kesalahan kalebu komponen DC-dadi luwih aman tinimbang Tipe AC ing skenario nyata.


Q3: Apa RCCB iki nyedhiyakake kakehan utawa proteksi short-circuit?

A3: Ora. Iki RCCB murni (ora ana pangayoman overcurrent). Sampeyan kudu digunakake ing seri karo MCB utawa sekring kanggo nglindhungi saka overloads lan short circuits.


Q4: Bisa digunakake ing sistem TT earthing?

A4: Ya-Tipe A Sisa Circuit Breakers umume digunakake ing sistem TT, utamané karo 100mA utawa 300mA kanggo pangayoman geni ing incomer, lan 30mA kanggo sirkuit final.


Q5: Napa milih CDADA tinimbang merek Tipe A liyane?

A5: CDADA nawakake:

● Kepatuhan IEC 61008-1 sing bener karo laporan tes

● Pilihan terminal dual (lug/pin) kanggo kabel fleksibel

● Status kontak kode warna (abang/ijo)

● Desain Surge-imun-ora lelungan palsu

● OEM-siap: rega akeh, dokumentasi Inggris, sampling cepet

Type A Residual Current Circuit Breaker



Hot Tags: Tipe A Sisa Circuit Breaker, China, Produsen, Supplier, Pabrik
Kirim Pitakonan
Info kontak

Mbukak kunci Solusi Listrik Kustom Sampeyan ing 24 Jam!

Napa takon karo Produsen Cina Top-Tier?

✅ Harga Pabrik Langsung

Cut biaya middleman! Minangka pabrik sing disertifikasi ISO 9001 ing China, kita ngirimake MCCB premium, MCB, lan pemutus DC solar kanthi tarif sing kompetitif-didhukung dening sertifikasi CE, KEMA, lan ASTA.

✅ 40+ Taun Keahlian OEM/ODM

Ngowahi casing, label, utawa spek teknis kanthi gampang. Tim R&D kita (60+ paten) nangani:

Tegangan khusus / rating saiki

Kemasan branded

Prototyping cepet (sampel ing 7 dina)

✅ Kapasitas Tahunan 3 Juta + Unit

Ora ana pesenan sing gedhe banget utawa urgent! Pabrik 52.400㎡ njamin:

◆ kaping timbal 15 dina kanggo pesenan akeh

◆ MOQ fleksibel

◆ Tes ASTM/UL sing ketat

✅ Kepatuhan Global, Ora Repot

Kita ngatasi alangan ekspor kanggo 45+ negara:

Dokumentasi RoHS/REACH

Sertifikasi khusus wilayah

Pemutus DC Solar kanggo proyek ijo EU

X
Kita nggunakake cookie kanggo menehi pengalaman browsing sing luwih apik, nganalisa lalu lintas situs lan nggawe konten pribadi. Kanthi nggunakake situs iki, sampeyan setuju kanggo nggunakake cookie.Kebijakan Privasi
nolakNampa